The date of discharge execution20-07-07 17:33:53 [Shot logbook]
The session missionCommissionings --> Strip Detector
The session ID33391
The discharge commentStandard test discharge
Discharge command./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 10 --Bt_orientation CW --CD_orientation CW --comment "Standard test discharge"

    Technological parameters:

    Plasma parameters:

  • Discharge duration: \(\tau\sub{p}\)=8,43 ms
  • Loop voltage:\(\overline{U\sub{loop}}\)\(\)=8,70 V; \(\maximum{{\tau \in [discharge]}U\sub{loop}}\)=15,49 V
  • Toroidal magnetic field: \(\overline{B\sub{t}}\)=0,19 T; \(\max_{\tau \in [discharge]}B\sub{t}\)=0,27 T
  • Plasma current: \(\overline{I\sub{p}}\)=2,05 kA; \(\max_{\tau \in [discharge]}I\sub{p}\)=2,45 kA

Basic diagnostics

Data Acquisition Systems (DAS)

StandardDAS

data dir

Diagnostics Systems

StripDetector

data dir

Analysis

0. wave:

BasicDiagnostics

data dir
Homepage

data dir
1. wave:

2. wave:

Infrastructure

Chamber

data dir
Charger

data dir
Discharge

data dir
Operator

data dir

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

Analysis

  • --
  • --

DASs

Vacuum log

Other