\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem No: 34130 - the only fully opensource tokamak

Tokamak GOLEM - Shot Database - 34130

[Web log]
The date of discharge execution20-11-12 18:49:31 [Shot logbook]
The session mission --> Electrostatic probes
The session ID34120
The discharge commentKepco offset -30V, FG 1->10 kHz
Discharge command./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 10 --Bt_orientation CW --CD_orientation CW --comment "Kepco offset -30V, FG 1->10 kHz"

    Technological parameters:

    Plasma parameters:

  • Discharge duration: \(\tau\sub{p}\)=9,93 ms
  • Loop voltage:\(\overline{U\sub{loop}}\)\(\)=8,10 V; \(\maximum{{\tau \in [discharge]}U\sub{loop}}\)=16,33 V
  • Toroidal magnetic field: \(\overline{B\sub{t}}\)=0,20 T; \(\max_{\tau \in [discharge]}B\sub{t}\)=0,29 T
  • Plasma current: \(\overline{I\sub{p}}\)=2,81 kA; \(\max_{\tau \in [discharge]}I\sub{p}\)=3,33 kA

Basic diagnostics

Diagnostics Systems

IDSetupDAS DeviceRaw DataAnalysisFiles
Data flow
->
->
->

Infrastructure

Chamber

data dir
Charger

data dir

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

DASs

Vacuum log

Other

Navigation