\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem No: 34409 - the only fully opensource tokamak

Tokamak GOLEM - Shot Database - #34409

[Web log]
The date of discharge execution20-12-15 12:42:39 [Shot logbook]
The session missionTrainingCourses --> MIPT Moscow
The session ID34371
The discharge commentNational Research Nuclear University MEPhI Group 2 KatkaH another oscilloscope E y axis range test
Discharge command./Dirigent.sh --discharge --UBt 600 --TBt 0 --Ucd 400 --Tcd 0 --preionization 1 --gas H --pressure 16 --comment "National Research Nuclear University MEPhI Group 2 KatkaH another oscilloscope E y axis range test"

    Technological parameters:

    Plasma parameters:

  • Discharge duration: \(\tau\sub{p}\)=9,93 ms
  • Loop voltage:\(\overline{U\sub{loop}}\)\(\)=5,30 V; \(\maximum{{\tau \in [discharge]}U\sub{loop}}\)=14,55 V
  • Toroidal magnetic field: \(\overline{B\sub{t}}\)=0,16 T; \(\max_{\tau \in [discharge]}B\sub{t}\)=0,23 T
  • Plasma current: \(\overline{I\sub{p}}\)=3,57 kA; \(\max_{\tau \in [discharge]}I\sub{p}\)=4,55 kA

Basic Diagnostics

Data flowmeasurement →digitization →analysis →saving →plotting →
NameExperiment setupData acquistition systemRaw dataAnalysis resultsAll filesData processing

On Stage Diagnostics: Training courses

Note: Click any image in the table below for more detailed information on each stage.
Data flowmeasurement →digitization →saving →
NameExperiment setupData acquistition systemRaw dataAll files

Infrastructure

Chamber

data dir
Charger

data dir

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

DASs

Vacuum log

Other

Navigation