\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem No: 34420 - the only fully opensource tokamak

Tokamak GOLEM - Shot Database - #34420

[Web log]
The date of discharge execution20-12-17 13:01:53 [Shot logbook]
The session missionTrainingCourses --> Training course for TU Torino
The session ID34415
The discharge commentTesty nastaveni Rogowskeho pasku: po uprave rozsahu Ch3 osciloskopu 100mV->200mV
Discharge command./Dirigent.sh --discharge --UBt 1000 --TBt 1000 --Ucd 500 --Tcd 2000 --preionization 1 --gas H --pressure 10 --comment "Testy nastaveni Rogowskeho pasku: po uprave rozsahu Ch3 osciloskopu 100mV->200mV"

    Technological parameters:

    Plasma parameters:

  • Discharge duration: \(\tau\sub{p}\)=11,55 ms
  • Loop voltage:\(\overline{U\sub{loop}}\)\(\)=7,38 V; \(\maximum{{\tau \in [discharge]}U\sub{loop}}\)=12,07 V
  • Toroidal magnetic field: \(\overline{B\sub{t}}\)=0,27 T; \(\max_{\tau \in [discharge]}B\sub{t}\)=0,38 T
  • Plasma current: \(\overline{I\sub{p}}\)=3,99 kA; \(\max_{\tau \in [discharge]}I\sub{p}\)=4,87 kA

Basic Diagnostics

Data flowmeasurement →digitization →analysis →saving →plotting →
NameExperiment setupData acquistition systemRaw dataAnalysis resultsAll filesData processing

On Stage Diagnostics: Training courses

Note: Click any image in the table below for more detailed information on each stage.
Data flowmeasurement →digitization →saving →
NameExperiment setupData acquistition systemRaw dataAll files

Infrastructure

Chamber

data dir
Charger

data dir

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

DASs

Vacuum log

Other

Navigation