\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem No: 34424 - the only fully opensource tokamak

Tokamak GOLEM - Shot Database - #34424

[Web log]
The date of discharge execution20-12-17 15:47:46 [Shot logbook]
The session missionTrainingCourses --> Training course for TU Torino
The session ID34422
The discharge commentStandard test discharge
Discharge command./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 10 --Bt_orientation CW --CD_orientation CW --comment "Standard test discharge"

    Technological parameters:

    Plasma parameters:

  • Discharge duration: \(\tau\sub{p}\)=9,12 ms
  • Loop voltage:\(\overline{U\sub{loop}}\)\(\)=8,44 V; \(\maximum{{\tau \in [discharge]}U\sub{loop}}\)=16,69 V
  • Toroidal magnetic field: \(\overline{B\sub{t}}\)=0,20 T; \(\max_{\tau \in [discharge]}B\sub{t}\)=0,29 T
  • Plasma current: \(\overline{I\sub{p}}\)=2,69 kA; \(\max_{\tau \in [discharge]}I\sub{p}\)=3,06 kA

Basic Diagnostics

Data flowmeasurement →digitization →analysis →saving →plotting →
NameExperiment setupData acquistition systemRaw dataAnalysis resultsAll filesData processing

On Stage Diagnostics: Training courses

Note: Click any image in the table below for more detailed information on each stage.
Data flowmeasurement →digitization →saving →
NameExperiment setupData acquistition systemRaw dataAll files

Infrastructure

Chamber

data dir
Charger

data dir

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

DASs

Vacuum log

Other