\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem No: 36352

Tokamak GOLEM - Shot Database - #36352

The date of discharge execution21-03-31 14:10:36 [Shot logbook]
The session mission21_EDU_SashaM_etal --> EDU
The session ID36341
The discharge commentMirnov coils configuration tests, now with mc1 and with mc9
Discharge command./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 15 --comment "Mirnov coils configuration tests, now with mc1 and with mc9" --diagnostics_biasingelectrode "5000,1;6000,1;9000,0;15000,0" --diagnostics_doublerakeprobe "r_First_Tip=85, X_mod=111111111110" --diagnostics_petiprobe "r_LP_tip=95, is_bpp=1, is_lp=1" --ScanDefinition 36349 36350 36351

     Technological parameters

    Plasma:

    Plasma parameters:

Basic Diagnostics    

On stage diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 

         



 

         



 

         



 

Other diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 

         



 

Analysis

NameAnalysis results


Name Python3 Gnuplot Octave Matlab Mathematica

Infrastructure







Scan issues

for 36349 36350 36351 + 36352







#36349     ./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 15 --comment "integral test cont." --diagnostics_biasingelectrode "5000,0;6000,0;9000,0;15000,0" --diagnostics_doublerakeprobe "r_First_Tip=85, X_mod=111111111110" --diagnostics_petiprobe "r_LP_tip=95, is_bpp=1, is_lp=1" --ScanDefinition
#36350     ./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 15 --comment "Without mc1" --diagnostics_biasingelectrode "5000,1;6000,1;9000,0;15000,0" --diagnostics_doublerakeprobe "r_First_Tip=85, X_mod=111111111110" --diagnostics_petiprobe "r_LP_tip=95, is_bpp=1, is_lp=1" --ScanDefinition
#36351     ./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 15 --comment "with mc1 Without mc9" --diagnostics_biasingelectrode "5000,1;6000,1;9000,0;15000,0" --diagnostics_doublerakeprobe "r_First_Tip=85, X_mod=111111111110" --diagnostics_petiprobe "r_LP_tip=95, is_bpp=1, is_lp=1" --ScanDefinition
#36352     ./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 15 --comment "Mirnov coils configuration tests, now with mc1 and with mc9" --diagnostics_biasingelectrode "5000,1;6000,1;9000,0;15000,0" --diagnostics_doublerakeprobe "r_First_Tip=85, X_mod=111111111110" --diagnostics_petiprobe "r_LP_tip=95, is_bpp=1, is_lp=1" --ScanDefinition 36349 36350 36351