\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem #38062

Tokamak GOLEM - Shot Database - #38062

The date of discharge execution22-02-13 10:34:55 [Shot logbook]
The session mission21_SOC_MatyasP_PetrS_PetrM --> Tunnel Probe
The session ID38055
The discharge commentTP U = -105 V, r = 70 mm, angle = 10
Discharge command./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 550 --Tcd 2000 --preionization 1 --gas H --pressure 10 --diagnostics.limitermirnovcoils "vacuum_shot=38057" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-10;15000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;7000,-20;15000,0;19000,0;22000,0'" --ScanDefinition "38061" --comment "TP U = -105 V, r = 70 mm, angle = 10"

     Technological parameters

    Plasma:

    Plasma parameters:

Basic Diagnostics    

On stage diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



         



 



Other diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



         



 



         



 



Analysis

NameAnalysis results


Infrastructure

main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-10;15000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;7000,-20;15000,0;19000,0;22000,0'




Scan issues

for 38061 + 38062







#38061     ./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 550 --Tcd 2000 --preionization 1 --gas H --pressure 10 --diagnostics.limitermirnovcoils "vacuum_shot=38057" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-10;15000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;7000,-20;15000,0;19000,0;22000,0'" --ScanDefinition "" --comment "TP U = -105 V, r = 70 mm, angle = 0"
#38062     ./Dirigent.sh --discharge --UBt 1200 --TBt 1000 --Ucd 550 --Tcd 2000 --preionization 1 --gas H --pressure 10 --diagnostics.limitermirnovcoils "vacuum_shot=38057" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;7000,-10;15000,0;25000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;7000,-20;15000,0;19000,0;22000,0'" --ScanDefinition "38061" --comment "TP U = -105 V, r = 70 mm, angle = 10"

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @