\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem #39147

Tokamak GOLEM - Shot Database - #39147

The date of discharge execution22-05-18 12:30:17 [Shot logbook]
The session missionGOLEM_II --> EDU (MHD + biasing)
The session ID39143
The discharge commentPlasma, VertStab
Discharge command./Dirigent.sh --discharge --UBt 1200 --TBt 0 --Ucd 450 --Tcd 350 --preionization 1 --gas H --pressure 10 --diagnostics.limitermirnovcoils "vacuum_shot=39109" --discharge.preionization "main_switch='on',powsup_heater=80,powsup_accel=100" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;8000,-15;15000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;9000,0;12000,0;24000,-2;25000,0'" --ScanDefinition "39146" --comment "Plasma, VertStab"

     Technological parameters

    Plasma:

    Plasma parameters:

Basic Diagnostics    

On stage diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



         



 



         



 



         



 



         



 



         



 



         



 



Other diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 



       

Analysis

NameAnalysis results

Infrastructure

main_switch='on',radial_switch='on',vertical_waveform='3000,0;8000,-15;15000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;9000,0;12000,0;24000,-2;25000,0'










Scan issues

for 39146 + 39147







#39146     ./Dirigent.sh --discharge --UBt 1200 --TBt 0 --Ucd 450 --Tcd 350 --preionization 1 --gas H --pressure 10 --diagnostics.limitermirnovcoils "vacuum_shot=39109" --discharge.preionization "main_switch='on',powsup_heater=80,powsup_accel=100" --discharge.position_stabilization "main_switch='off',radial_switch='on',vertical_waveform='3000,0;11000,-20;22000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;9000,0;12000,-20;24000,0;25000,0'" --ScanDefinition "39121 39124 39125" --comment "Plasma, reference"
#39147     ./Dirigent.sh --discharge --UBt 1200 --TBt 0 --Ucd 450 --Tcd 350 --preionization 1 --gas H --pressure 10 --diagnostics.limitermirnovcoils "vacuum_shot=39109" --discharge.preionization "main_switch='on',powsup_heater=80,powsup_accel=100" --discharge.position_stabilization "main_switch='on',radial_switch='on',vertical_waveform='3000,0;8000,-15;15000,0;30000,0',vertical_switch='on',radial_waveform='2000,0;3000,0;9000,0;12000,0;24000,-2;25000,0'" --ScanDefinition "39146" --comment "Plasma, VertStab"

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @