Tokamak GOLEM - Shot Database - #41951 
The date of discharge execution | 23-05-24 16:29:49 [Shot logbook] |
---|
The session mission | TrainingCourses/Universities/MEPhI.ru/23BiasingAndMHD --> MHD studies with biasing  |
---|
The session ID | 41937  |
---|
The discharge comment | R_BE=60, r_DRP=60 zero inductor |
---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on',vacuum_shot=!925'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,O_Bt='CW',U_cd=450,t_cd=0,O_cd= ... |
Plasma:

Plasma parameters:
On stage diagnostics
Data flow | measurement → | digitization → | analysis → | |
Name | Experiment setup | Data acquistition system | Raw data | Analysis results |
|
 |
 |
 |


|
 |

☛

|
|
 |
 |
 |


|
Off stage diagnostics
Data flow | measurement → | digitization → | analysis → | |
Name | Experiment setup | Data acquistition system | Raw data | Analysis results |
|
 |
 |
 |


|
 |

☛

|
|
 |
 |
 |


|
|
 |
 |
 |


|
 |

☛

|
|
 |
 |
 |


|
 |

☛

|
|
 |
 |
 |


|
|
 |
 |
 |


|
|
 |
 |
 |


|
Analysis
Infrastructure
Working gas:S_mode='p_wg',S_gas='H',p_H=12 |
   |
Bt, Ecd:U_Bt=1000,t_Bt=0,O_Bt='CW',U_cd=450,t_cd=0,O_cd='CW' |


|
Position stabilization: main_switch='on',vertical_switch='on',vertical_waveform='3000,0;7000,-5;8000,-20;30000,0',radial_switch='on',radial_waveform='2000,0;3000,-5;5000,-20;30000,0' |
 |
 |
 |
 |
 |
 |
 |

☛

|
Biasing electrode:main_switch='on',waveform='1000,0;5000,20;7500,-20;10000,0;14000,0' |
 |
 |
 |


|
|

|
The tokamak GOLEM is now in the Standby mode.
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 