Tokamak GOLEM - Shot Database - #42122
The date of discharge execution | 23-06-07 09:59:34 [Shot logbook] |
---|
The session mission | TrainingCourses/Universities/MEPhI.ru/23BiasingAndMHD --> MHD studies with biasing |
---|
The session ID | 42122 |
---|
The discharge comment | Master standard initiation discharge |
---|
Discharge command | /Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=450,t_cd=0,O_cd='CW'" --infrastructure.pr ... |
Plasma:
Plasma parameters:
On stage diagnostics
Data flow | measurement → | digitization → | analysis → | |
Name | Experiment setup | Data acquistition system | Raw data | Analysis results |
|
|
|
|
|
|
☛
|
DoubleRakeProbe:r_First_Tip=100,X_mod='111111111111',I_SilverBox=0 |
|
|
|
|
|
RakeProbe:r_First_Tip=100,phi_First_Tip=0,X_mod='111111111111',I_SilverBox=12,r_manipulator=70,phi_manipulator=0 |
|
|
|
|
|
Off stage diagnostics
Data flow | measurement → | digitization → | analysis → | |
Name | Experiment setup | Data acquistition system | Raw data | Analysis results |
Interferometry: |
|
|
|
|
|
|
☛
|
|
|
|
|
|
LimiterMirnovCoils:vacuum_shot=-1 |
|
|
|
|
|
|
|
|
|
|
|
☛
|
ScintillationProbes:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Analysis
Infrastructure
Working gas:S_mode='U_v',S_gas='H',U_v=20.5,p_H=-1 |
|
Bt, Ecd:U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=450,t_cd=0,O_cd='CW' |
|
Position stabilization: main_switch='on',vertical_switch='on',vertical_waveform='3000,0;7000,-5;8000,-20;30000,0',radial_switch='on',radial_waveform='2000,0;3000,-5;5000,-20;30000,0' |
|
|
|
|
|
|
|
☛
|
Biasing electrode:main_switch='on',waveform='1000,0;2000,-10;5000,0;6000,0;14000,0' |
|
|
|
|
|
|
The tokamak GOLEM is now in the Standby mode.
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @