Tokamak GOLEM - Shot Database - #50859

Plasma:

Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:


Double rake probe Data flow:


Parameters:r_first_tip=100,X_mod='111111111111',I_SilverBox=0
Rake probe Data flow:

Double langmuir ball pen probe Data flow:

Off stage diagnostics
Interferometry Data flow:


Fast cameras Data flow:



Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=40,width_ux100a=1280,fr_ux100b=1
Slow optical spectrometry Data flow:

Scintillation probes Data flow:


Parameters:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600
Fast spectrometry Data flow:

Magnetohydrodynamic 16 mirnov coils ring Data flow:

Analysis
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=900,t_Bt=0,U_cd=400,t_cd=200,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=12,U_v=0
Preionization
Parameters
:S_device='HotCathode',SW_main='on',U_heater=90,U_accel=100
Position stabilization
:
Parameters
:main_switch='off',radial_switch='on',radial_waveform='1000,0;3000,0;10000,10;25000,15;30000,15;40000,15;50000,0',vertical_switch='on',vertical_waveform='1000,0;6000,0;10000,-10;13000,-10;15000,-10;19000,-8;48000,-8;50000,0'
Current stabilization
Parameters
:main_switch='on',waveform='1000,0;10000,0;15000,-10;22000,-10;30000,0'
 |
 |
 |
Biasing electrode 
Parameters
:main_switch='on',waveform='1000,0;3000,-20;15000,0;30000,0',position=100"
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 