RE session (13. 7. - 17.7. 2020)

#Aim of experiment

#Short description

#Experimental setup

##Detectors

##Experimental overlay

#Logbook

##First day (13.7.)

  • baking and glow dischage before start of session
  • installation of detectors - 2x NaI(Tl) (Envinet, ORTEC), 3x YAP(Ce) (2x Scionix, Crytur)

##Second day (14.7.)

  • before start of the session all PMTs set to \(600 V\)

###33580

  • first shot of Tuesday session
  • without scintillation detectors
  • quite long (with low value of \(U_{BT}\)

###33581

  • detectors switched on
  • repeat of previous discharge
  • unsucessfull - something was wrong - setting was wrong (\(U_{BT}\) was set to \(8000 \ \mathrm{V}\))

###33582

  • dummny discharge

###33583

  • test discharge

###33584

  • standard test discharge

###33585

  • standard test discharge

###33586

  • repeat of standard discharge with scin. detectors

###33587

  • repeat of standard discharge with scin. detectors
  • burst of HXR after breakdown

###33588

  • repeat of standard discharge with scin. detectors
  • burst of HXR after breakdown

###33589

  • YAP_CRY is back on its position near old NaI(Tl)
  • repeat of standard discharge with scin. detectors
  • burst of HXR after breakdown

###33590

  • YAP_CRY is back on its position near old NaI(Tl)
  • repeat of standard discharge with scin. detectors and with detector in old position (!!!)
  • burst of HXR after breakdown

###NOTE I

  • probably asymmertry seen by YAP_CRY?

###33591

  • burst of HXR is vanishing at the beginning on YAP detectors

###33592

  • start of pressure scan: \(p_{gas} = 10 \ \mathrm{mPa}\), same setting as STD

###33593

  • again previous, \(p_{gas} = 10 \ \mathrm{mPa}\)

###33594

  • again previous, \(p_{gas} = 10 \ \mathrm{mPa}\)

###33595

  • again previous, \(p_{gas} = 10 \ \mathrm{mPa}\)

###33596

  • again previous, \(p_{gas} = 10 \ \mathrm{mPa}\)

###33597

  • \(p_{gas} = 12 \ \mathrm{mPa}\)

###33598

  • \(p_{gas} = 12 \ \mathrm{mPa}\)

###33599

  • \(p_{gas} = 12 \ \mathrm{mPa}\)

###33600

repeat, something wrong -> OK \(p_{gas} = 12 \ \mathrm{mPa}\)

###33601

  • everything OK
  • \(p_{gas} = 12 \ \mathrm{mPa}\)

###33602

  • \(p_{gas} = 14 \ \mathrm{mPa}\)

###33603

  • \(p_{gas} = 14 \ \mathrm{mPa}\)

###33604

  • \(p_{gas} = 14 \ \mathrm{mPa}\)

###33605

  • \(p_{gas} = 14 \ \mathrm{mPa}\)

###33605

  • \(p_{gas} = 14 \ \mathrm{mPa}\)

###33606

  • \(p_{gas} = 14 \ \mathrm{mPa}\)

###33607

  • \(p_{gas} = 14 \ \mathrm{mPa}\)
  • but different magnetic field, back to ST settting

###33608

  • \(p_{gas} = 14 \ \mathrm{mPa}\)
  • after lunch
  • with decreased magnetic field, first burst of HXR disapperd

###33608

  • \(p_{gas} = 14 \ \mathrm{mPa}\)

###33610

  • \(p_{gas} = 14 \ \mathrm{mPa}\)

###33611

  • \(p_{gas} = 16 \ \mathrm{mPa}\)

###33612

  • \(p_{gas} = 16 \ \mathrm{mPa}\)

###33613

  • \(p_{gas} = 16 \ \mathrm{mPa}\)

###33614

  • \(p_{gas} = 16 \ \mathrm{mPa}\)

###33615

  • \(p_{gas} = 16 \ \mathrm{mPa}\)

###33616

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33617

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33618

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33619

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33620

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33620

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33620

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33620

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33621

  • \(p_{gas} = 18 \ \mathrm{mPa}\)

###33622

  • \(p_{gas} = 20 \ \mathrm{mPa}\)

###33623

  • \(p_{gas} = 20 \ \mathrm{mPa}\)

###33624

  • \(p_{gas} = 20 \ \mathrm{mPa}\)

###33625

  • \(p_{gas} = 20 \ \mathrm{mPa}\)

###33626

  • \(p_{gas} = 20 \ \mathrm{mPa}\)

###33627

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33628

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33629

  • \(p_{gas} = 22 \ \mathrm{mPa}\)
  • wrong pressure, again

###33630

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33631

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33632

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33633

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33634

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33635

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33636

  • \(p_{gas} = 22 \ \mathrm{mPa}\)

###33637

  • \(p_{gas} = 24 \ \mathrm{mPa}\)

###33638

  • \(p_{gas} = 24 \ \mathrm{mPa}\)

###33639

  • \(p_{gas} = 24 \ \mathrm{mPa}\)

###33640

  • \(p_{gas} = 24 \ \mathrm{mPa}\)

###33641

  • \(p_{gas} = 26 \ \mathrm{mPa}\)

###33642

  • \(p_{gas} = 26 \ \mathrm{mPa}\)

###33643

  • \(p_{gas} = 26 \ \mathrm{mPa}\)

###33644

  • \(p_{gas} = 26 \ \mathrm{mPa}\)

###33645

  • \(p_{gas} = 26 \ \mathrm{mPa}\)

###33645

  • \(p_{gas} = 26 \ \mathrm{mPa}\)

###33646

  • \(p_{gas} = 26 \ \mathrm{mPa}\)
  • completely wrong pressure

###33646

  • \(p_{gas} = 26 \ \mathrm{mPa}\)

###33646

  • \(p_{gas} = 26 \ \mathrm{mPa}\)

##Third day (17.7.)