Production/Wanted/RawIdeas/ProbeMeasurements/JA_Re: ball-pen sonda.eml

Received: from BRK2.fjfi.cvut.cz (147.32.9.22) by MRK2.fjfi.cvut.cz
 (147.32.9.23) with Microsoft SMTP Server (TLS) id 14.3.181.6; Mon, 26 May
 2014 11:02:56 +0200
Received: from mailgw1.fjfi.cvut.cz (147.32.9.3) by BRK2.fjfi.cvut.cz
 (147.32.9.22) with Microsoft SMTP Server (TLS) id 14.3.181.6; Mon, 26 May
 2014 11:02:55 +0200
Received: from mailgw1.fjfi.cvut.cz (localhost [127.0.0.1])	(using TLSv1.2
 with cipher ECDHE-RSA-AES256-GCM-SHA384 (256/256 bits))	(No client
 certificate requested)	by mailgw1.fjfi.cvut.cz (Postfix) with ESMTPS id
 BFF2CC0052	for <svoboda@fjfi.cvut.cz>; Mon, 26 May 2014 11:02:55 +0200 (CEST)
Received: from localhost (localhost [127.0.0.1])	by mailgw1.fjfi.cvut.cz
 (Postfix) with ESMTP id AF91EC004B	for <svoboda@fjfi.cvut.cz>; Mon, 26 May
 2014 11:02:55 +0200 (CEST)
X-Quarantine-ID: <VdFj_1bKr676>
X-CTU-FNSPE-Virus-Scanned: amavisd-new at fjfi.cvut.cz
X-CTU-FNSPE: this_is_mailgw_for_ctu_fnspe_header
X-CTU-FNSPE-Helo: mail.tok.ipp.cas.cz
X-CTU-FNSPE-Client-Address: 147.231.37.220
X-CTU-FNSPE-Client-Name: UFP7220.ipp.cas.cz
X-CTU-FNSPE-Sender: adamek@ipp.cas.cz
X-CTU-FNSPE-Recip: svoboda@fjfi.cvut.cz
X-CTU-FNSPE-Amavis-OS-Fingerprint: Linux 3.x; dist: 7; link: Ethernet or
	modem; params: none; raw_mtu: 1500; raw_sig:
	4:57+7:0:1460:mss*10,7:mss,sok,ts,nop,ws:df,id+:0,
	[147.231.37.220]:60816
X-Amavis-OS-Fingerprint: Linux 3.x; dist: 7; link: Ethernet or modem; params:
	none; raw_mtu: 1500; raw_sig:
	4:57+7:0:1460:mss*10,7:mss,sok,ts,nop,ws:df,id+:0,
	[147.231.37.220]:60816
Received: from mailgw1.fjfi.cvut.cz ([127.0.0.1])	by localhost
 (mailgw1.fjfi.cvut.cz [127.0.0.1]) (amavisd-new, port 10024)	with ESMTP id
 VdFj_1bKr676 for <svoboda@fjfi.cvut.cz>;	Mon, 26 May 2014 11:02:53 +0200
 (CEST)
Received: from mail.tok.ipp.cas.cz (UFP7220.ipp.cas.cz [147.231.37.220])	by
 mailgw1.fjfi.cvut.cz (Postfix) with ESMTP id B1864C003A	for
 <svoboda@fjfi.cvut.cz>; Mon, 26 May 2014 11:02:52 +0200 (CEST)
DKIM-Filter: OpenDKIM Filter v2.9.0 mailgw1.fjfi.cvut.cz B1864C003A
X-SenderID: Sendmail Sender-ID Filter v1.0.0 mailgw1.fjfi.cvut.cz B1864C003A
Received: from mail.tok.ipp.cas.cz (localhost [127.0.0.1])	by
 mail.tok.ipp.cas.cz (Postfix) with ESMTP id 514B264020C;	Mon, 26 May 2014
 11:02:52 +0200 (CEST)
Content-Type: text/plain; charset="UTF-8"; format=flowed
Content-Transfer-Encoding: 7bit
Date: Mon, 26 May 2014 11:02:52 +0200
From: adamek <adamek@ipp.cas.cz>
To: Vojtech Svoboda <svoboda@fjfi.cvut.cz>
CC: =?UTF-8?Q?Jan_St=C3=B6ckel?= <stockel@ipp.cas.cz>
Subject: Re: ball-pen sonda
In-Reply-To: <53810A99.1030401@fjfi.cvut.cz>
References: <4070cb0801f468f35e2fb61e741130c1@ipp.cas.cz>
 <53810A99.1030401@fjfi.cvut.cz>
Message-ID: <80849e3ad78ca86b96ae959894f3596b@ipp.cas.cz>
X-Sender: adamek@tok.ipp.cas.cz
User-Agent: Roundcube Webmail/0.9.2
Return-Path: adamek@ipp.cas.cz
X-MS-Exchange-Organization-PRD: ipp.cas.cz
Received-SPF: None (BRK2.fjfi.cvut.cz: adamek@ipp.cas.cz does not designate
 permitted sender hosts)
X-MS-Exchange-Organization-AVStamp-Mailbox: MSFTFF;1;0;0 0 0
X-MS-Exchange-Organization-SenderIdResult: NONE
X-MS-Exchange-Organization-AuthSource: BRK2.fjfi.cvut.cz
X-MS-Exchange-Organization-AuthAs: Anonymous
MIME-Version: 1.0

  Ahoj Vojto,
tak to je super. Jinak bych se mohl pomoct s experimentem. Z casovych 
duvodu bych nemohl byt na Golemu uplne kazdy tyden, ale myslim, ze po 
porade s R. Pankem by to nejak slo. Hlavice s ball-pen sondou a 
Lagnmuirovou sondou je pripravena. Tak trochu jsem myslel, ze o tom vis 
od pana doktora Stockela.
Jinak v kratkosti: ball-pen sonda mereni primo potencial plazmatu 
(radialni a poloidalni electricke pole) a v kombinaci s Langmuirovou 
sondou, merime i eletronovou teplotu bez zdroje s vysokym casovym 
rozlisenim. V soucasne dobe, je jiz pomerne jasne, ze radial particle 
flux se musi pocitac primo s mereni potencialu plazmatu a nikoli s 
nahrazkou pomoci plovouciho potencialu, viz. experiment na ISTTOKu, 
ktery je v clanku na wikipedii u ball-pen sondy.

S pozdravem
Jirka


---
Mgr. Jiri Adamek Ph.D.
Institute of Plasma Physics AS CR, v.v.i.
Za Slovankou 1782/3, 182 00 Prague 8, Czech Republic
+420 266 052 961

Dne 24.05.2014 23:09, Vojtech Svoboda napsal:
> Ahoj Jirko, zalozil jsem strohou stranku, viz
> http://golem.fjfi.cvut.cz/wiki/Diagnostics/ParticleFlux/BallPenProbe/index
> 
> Pokud je neco pripraveno k instalaci na GOLEMa, rad bych to zkusil
> instalovat a trochu si s tim nekdy pohrat. Ale nemam nikoho, kdo by
> tento experiment "vedl", tak uplne nevim. Mej se. Vojta
> 
> On 05/24/2014 06:20 PM, adamek wrote:
>>  Ahoj Vojto,
>> vzhledem k tomu, ze se ball-pen sonda drive pouzivala na tokamaku
>> CASTOR a rozvnez o ni mate zminku na svych strankach, poprosil bych
>> te, jestli muzes umistit odkaz na wikipedii o ball-pen sonde na vase
>> stranky. Studenti by se tak snadno mohli dozvedet vic o principu a
>> mereni s touto sondou. Jinak hlavice s ball-pen a Langmuirovou sondou
>> je pripravena i pro tokamak Golem, pokud by si mel zajem pokracovat v
>> mereni touto diagnostikou. Budu rad za tve pripominky nebo navrhy.
>> Zde je stranka s ball-pen sondu
>> 
>> https://en.wikipedia.org/wiki/Ball-pen_probe
>> 
>> Mozna by bylo fajn, kdyby vas tokamak Golem byl take na
>> en.wikipeda.org , protoze v seznamu fuznich zarizenich na neho neni
>> odkaz.
>> 
>> S pozdravem
>> Jirka
>> 
>>