Navigation
current
next
|
previous
|
GOLEM
»
Shot #19785
»
Tokamak GOLEM - Shot Database - 19785
[Template source]
[WebLog]
Date:
2015-07-16 -
17:20:32
Session:
Training/2015/
Comment:
JakubMandula - Muj prvni vystrel
Basic parameters:
(
compare
)
Gas pressure p
ch
:
10.56
->
10.60
mPa (request:
20
mPa)
WIKI
Working gas:
H
Preionization: Upper el. gun
Chamber temperature:
60.00
C
C
B
t
capacitors charged to:
600 V
, triggered
5.0 ms
WIKI
C
BD
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
C
CD
capacitors charged to:
500 V
, triggered
6.0 ms
WIKI
C
ST
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
Probability of breakdown:
92%
WIKI
Time since session beginning: 1:20:44 h
Plasma parameters:
Plasma life time
6.9
[ms] (from
7.8
to
14.7
)
Mean toroidal magnetic field Bt:
0.13
T
WIKI
Mean plasma current:
1.28
kA
WIKI
Mean Uloop:
11.55
V
WIKI
Break down voltage:
11.5
V
WIKI
Ohmic heating power:
14.82
kW
Q edge:
4.4
WIKI
Electron temperature:
13.2
eV
WIKI
Line electron density:
N/A
[10^17.m^-2]
WIKI
WIKI
WIKI
WIKI
WIKI
basicdiagn processing evolution:
raw
→
integrated
→
final
Basic diagnostics:
loop_voltage
,
plasma_current
,
toroidal_field
,
photodiode
,
hxr
,
other diagnostics
Data Acquisition Systems (DAS):
NIstandard
Diagnostics:
PlasmaPosition_TO
Flukes
Interferometer_LM
Interferometer
Spectrometer
FastCamera
HXR
Analysis:
HistoricalAnalysis
ShotHomepage
AdvancedAnalysis
Spectrograms_TO
MultiCWT_TO
MWPreionization
Impurities_TO
Students:
Guests:
Acknowledgement:
Thanks to the specific help
and
Diagnostics
✕
PlasmaPosition_TO
✕
Flukes
✕
Interferometer_LM
✕
Interferometer
✕
Spectrometer
✕
FastCamera
✓
HXR
Analysis
✓
HistoricalAnalysis
✓
ShotHomepage
✓
AdvancedAnalysis
✓
Spectrograms_TO
✕
MultiCWT_TO
✓
MWPreionization
✕
Impurities_TO
DAS
✓
NIstandard
Vacuum log
Charging log
Other
Data
References
About
Wiki
Utilities
Navigation
Next
Previous
Current
Go to shot
[Main template]
Disk usage: 25MB
Navigation
current
next
|
previous
|