Shot #23009
»
Tokamak GOLEM - Shot Database - 23009
[Template source]
[WebLog]
Date:
2017-01-19 -
19:24:05
Session:
Experiments/EdgePlasmaPhysics/BallPenProbe/0117VAcharWithSweep
Comment:
DAS fail, repeat
Basic parameters:
(
compare
)
Gas pressure p
ch
:
0.18
->
20.43
mPa (request:
20
mPa)
WIKI
Working gas:
H
Preionization: Upper el. gun
Chamber temperature:
24.50
C
C
B
t
capacitors charged to:
1100 V
, triggered
5.0 ms
WIKI
C
BD
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
C
CD
capacitors charged to:
400 V
, triggered
5.0 ms
WIKI
C
ST
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
Probability of breakdown:
87%
WIKI
Time since session beginning: 0:20:41 h
Plasma parameters:
Plasma life time
17.8
[ms] (from
7.1
to
24.9
)
Mean toroidal magnetic field Bt:
0.32
T
WIKI
Mean plasma current:
4.01
kA
WIKI
Mean Uloop:
4.77
V
WIKI
Break down voltage:
9.9
V
WIKI
Ohmic heating power:
19.14
kW
Q edge:
3.6
WIKI
Electron temperature:
50.9
eV
WIKI
Line electron density:
7.08
[10^17.m^-2]
WIKI
WIKI
WIKI
WIKI
WIKI
WIKI
basicdiagn processing evolution:
raw
→
integrated
→
final
Basic diagnostics:
loop_voltage
,
plasma_current
,
toroidal_field
,
photodiode
,
hxr
,
other diagnostics
Data Acquisition Systems (DAS):
TektronixDPO
NIstandard
Papouch_St
NIoctopus
Diagnostics:
Interferometer
Spectrometer
FastCamera
HXR
Analysis:
ShotHomepage
AdvancedAnalysis
Students:
Guests:
Acknowledgement:
Thanks to the specific help
and
Diagnostics
✓
Interferometer
✓
Spectrometer
✕
FastCamera
✓
HXR
Analysis
✓
ShotHomepage
✓
AdvancedAnalysis
DAS
✓
TektronixDPO
✓
NIstandard
✓
Papouch_St
✓
NIoctopus
Vacuum log
Other
Data
References
About
Wiki
Utilities
Navigation
Next
Previous
Current
Go to shot
[Main template]
Disk usage: 37MB
Navigation
current
next
|
previous
|