[WebLog]
Date:
2017-09-21 -
19:39:50
Session:
Training/2017/
Comment:
Testy noveho log systemu a Fluke
Basic parameters:
(
compare
)
Gas pressure p
ch
:
0.17
->
21.00
mPa (request:
20
mPa)
WIKI
Working gas:
H
Preionization: Upper el. gun
Chamber temperature:
26.70
C
C
B
t
capacitors charged to:
700 V
, triggered
5.0 ms
WIKI
C
BD
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
C
CD
capacitors charged to:
550 V
, triggered
6.0 ms
WIKI
C
ST
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
Level of noise
(dBt)
in room:
0.007 V
Probability of breakdown:
92%
WIKI
Time since session beginning: 0:12:59 h
Plasma parameters:
Plasma life time
13.7
[ms] (from
7.5
to
21.2
)
Mean toroidal magnetic field Bt:
0.20
T
WIKI
Mean plasma current:
4.29
kA
WIKI
Mean Uloop:
7.99
V
WIKI
Break down voltage:
11.3
V
WIKI
Ohmic heating power:
34.31
kW
Q edge:
2.1
WIKI
Electron temperature:
37.8
eV
WIKI
Line electron density:
7.81
[10^17.m^-2]
WIKI
WIKI
WIKI
WIKI
WIKI
WIKI
basicdiagn processing evolution:
raw
→
integrated
→
final
Basic diagnostics:
loop_voltage
,
plasma_current
,
toroidal_field
,
photodiode
,
hxr
,
other diagnostics
Data Acquisition Systems (DAS):
TektronixDPO
RigolDS
NIstandard
Fluke
Diagnostics:
Interferometer
FastCamera
HXR
Analysis:
HistoricalAnalysis
GolemFusionPromo
ShotHomepage
AdvancedAnalysis
Students:
Guests:
Acknowledgement:
Thanks to the specific help
and
Diagnostics
✓
Interferometer
✕
FastCamera
✓
HXR
Analysis
✓
HistoricalAnalysis
✕
GolemFusionPromo
✓
ShotHomepage
✓
AdvancedAnalysis
DAS
✓
TektronixDPO
✕
RigolDS
✓
NIstandard
✕
Fluke
Vacuum log
Other
Data
References
About
Wiki
Utilities
Navigation
Next
Previous
Current
Go to shot
[Main template]
Disk usage: 14MB
Navigation
current
next
|
previous
|