Navigation
current
next
|
previous
|
GOLEM
»
Shot #25894
»
Tokamak GOLEM - Shot Database - 25894
[Template source]
[WebLog]
Date:
2018-01-18 -
11:58:24
Session:
Training/2018/
Comment:
MichFarn - pch = 44 mPa
Basic parameters:
(
compare
)
Gas pressure p
ch
:
0.59
->
29.22
mPa (request:
44
mPa)
WIKI
Working gas:
H
Preionization: Upper el. gun
Chamber temperature:
23.40
C
C
B
t
capacitors charged to:
800 V
, triggered
5.0 ms
WIKI
C
BD
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
C
CD
capacitors charged to:
400 V
, triggered
6.0 ms
WIKI
C
ST
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
Level of noise
(dBt)
in room:
0.007 V
Probability of breakdown:
66%
WIKI
Time since session beginning: 2:37:26 h
Plasma parameters:
Plasma life time
15.7
[ms] (from
8.4
to
24.1
)
Mean toroidal magnetic field Bt:
0.25
T
WIKI
Mean plasma current:
4.08
kA
WIKI
Mean Uloop:
4.59
V
WIKI
Break down voltage:
10.2
V
WIKI
Ohmic heating power:
18.74
kW
Q edge:
2.7
WIKI
Electron temperature:
52.9
eV
WIKI
Line electron density:
4.33
[10^17.m^-2]
WIKI
WIKI
WIKI
WIKI
WIKI
WIKI
basicdiagn processing evolution:
raw
→
integrated
→
final
Basic diagnostics:
loop_voltage
,
plasma_current
,
toroidal_field
,
photodiode
,
hxr
,
other diagnostics
Data Acquisition Systems (DAS):
TektronixDPO
RigolDS
RigolDS
NIstandard
Papouch_Za
Diagnostics:
Interferometer
Spectrometer
Analysis:
HistoricalAnalysis
ShotHomepage
AdvancedAnalysis
Impurities_TO
Students:
Guests:
Acknowledgement:
Thanks to the specific help
and
Diagnostics
✓
Interferometer
✕
Spectrometer
Analysis
✓
HistoricalAnalysis
✓
ShotHomepage
✓
AdvancedAnalysis
✕
Impurities_TO
DAS
✓
TektronixDPO
✕
RigolDS
✕
RigolDS
✓
NIstandard
✓
Papouch_Za
Vacuum log
Other
Data
References
About
Wiki
Utilities
Navigation
Next
Previous
Current
Go to shot
[Main template]
Disk usage: 42MB
Navigation
current
next
|
previous
|