\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem #44449

Tokamak GOLEM - Shot Database - #44449

The date of discharge execution24-04-11 10:29:45 [Shot logbook]
The session missionTrainingCourses/Universities/MEPhI.ru/24/Intro-CurrentStatusTraining course
The session ID 44449
The discharge commentStandard discharge
Discharge command/Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure ...

     Technological parameters

    No Plasma:

Basic Diagnostics    

On stage diagnostics

Basic diagnostics 

         

Off stage diagnostics

Interferometry 

         

Magnetohydrodynamic 16 mirnov coils ring 

         

Double rake probe 

         

Slow optical spectrometry 

         

Scintillation probes 

Parameters:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600
         

Langmuir & Ball-pen probe 

Parameters:r_lp_tip='80',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_d
         

Timepix detector 

         

Mirnov coils @ Limiter 

         

Fast spectrometry 

         

Infrastructure

Name Placement Experiment setup Photo gallery Raw data Dir
Chamber status (Working gas request:S_mode='U_v',S_gas='H',p_H=15,U_v=22)
Bt, Ecd:U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'
Position stabilization: main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'
 
 

Biasing electrode:






Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Navigation

Other