Tokamak GOLEM - Shot Database - #44475
Plasma:
Plasma parameters:
On stage diagnostics
Basic diagnostics
☛
Off stage diagnostics
Interferometry
☛
Fast cameras
☛
Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=30,width_ux100a=1280,fr_ux100b=1
Motion detection
|
N/A |
|
|
South
|
North
|
Magnetohydrodynamic 16 mirnov coils ring
Double rake probe
Parameters:r_first_tip=100,X_mod='22222222222',I_SilverBox=0
Slow optical spectrometry
Scintillation probes
Parameters:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600
Langmuir & Ball-pen probe
Parameters:r_lp_tip='80',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_d
Timepix detector
☛
Mirnov coils @ Limiter
Fast spectrometry
Analysis
Infrastructure
Name |
Placement |
Experiment setup |
Photo gallery |
Raw data |
Dir |
Chamber status (Working gas request:S_mode='U_v',S_gas='H',p_H=15,U_v=23.0) |
|
|
|
|
|
|
Bt, Ecd:U_Bt=800,t_Bt=0,U_cd=350,t_cd=1000,O_Bt='CW',O_cd='CW' |
|
|
|
|
|
|
Position stabilization: main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0,',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0' |
|
|
|
|
|
|
|
|
|
|
|
|
Biasing electrode:main_switch='on',waveform='1000,0;3000,-20;15000,0;30000,0',position=90 |
|
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @