Tokamak GOLEM - Shot Database - #45145

The date of discharge execution | 24-06-03 12:56:18 [Shot logbook] |
---|
The session mission | Diagnostics/Basic/Interferometry/CommissioningCommissioning  |
---|
The session ID  | 45136  |
---|
The discharge comment | Standard discharge |
---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'" --infrastructure ... |
Plasma:

Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Off stage diagnostics
Interferometry Data flow:

Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=500,t_cd=1000,O_cd='CW'
Preionization
Parameters

:S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100
Working gas
Parameters

:S_mode='U_v',S_gas='H',p_H=15,U_v=20
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 