Tokamak GOLEM - Shot Database - #45564
![](http://golem.fjfi.cvut.cz/_static/qr.png)
| 24-07-01 21:02:39 [Shot logbook] |
---|
The session mission | Experiments/PlasmaRegimes/0624OptimizationFull steam ![](http://golem.fjfi.cvut.cz/_static/postgresql.webp) |
---|
The session ID ![](http://golem.fjfi.cvut.cz/_static/history.png) | 45514 ![](http://golem.fjfi.cvut.cz/_static/postgresql.webp) |
---|
The discharge comment | searching good regime |
---|
Discharge command![](http://golem.fjfi.cvut.cz/_static/help.png) ![](http://golem.fjfi.cvut.cz/_static/direct.png) | /Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=950,t_Bt=0,U_cd=400,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S_ ... |
Plasma:
![](http://golem.fjfi.cvut.cz/_static/direct.png)
Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:
![](http://golem.fjfi.cvut.cz/_static/results.png)
Documentation:
Off stage diagnostics
Interferometry Data flow:
![](http://golem.fjfi.cvut.cz/_static/results.png)
Documentation:
Fast cameras Data flow:
![](http://golem.fjfi.cvut.cz/_static/results.png)
Documentation:
![](http://golem.fjfi.cvut.cz/_static/parameters.png)
Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=30,width_ux100a=1280,fr_ux100b=1
Motion detection ![](http://golem.fjfi.cvut.cz/_static/direct.png)
|
N/A |
|
![](Devices/AVs/PhotronMiniUX100-a/das.jpg) |
South
![](Diagnostics/FastCameras/Camera_South/1s.jpeg) |
North
![](Diagnostics/FastCameras/Camera_North/1s.jpeg) |
Double rake probe Data flow:
Documentation:
Parameters:r_first_tip=100,X_mod='111111111111',I_SilverBox=0
Slow optical spectrometry Data flow:
Documentation:
Scintillation probes Data flow:
Documentation:
Langmuir & Ball-pen probe Data flow:
Documentation:
Parameters:r_lp_tip='90',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_d
Timepix detector Data flow:
![](http://golem.fjfi.cvut.cz/_static/results.png)
Documentation:
Mirnov coils @ Limiter Data flow:
Documentation:
Fast spectrometry Data flow:
Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd
,![](http://golem.fjfi.cvut.cz/_static/direct.png)
Parameters
:U_Bt=950,t_Bt=0,U_cd=400,t_cd=350,O_Bt='CW',O_cd='CW'
Preionization
Parameters
:S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100
Working gas
Parameters
:S_mode='U_v',S_gas='H',p_H=10,U_v=10.2
Position stabilization
:
Parameters
:main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;24000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;24000,-20;30000,0'
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ ![](/_static/logos/GitLab.png)