Tokamak GOLEM - Shot Database - #45792

| 24-08-13 12:10:56 [Shot logbook] |
---|
The session mission | Infrastructure/CurrentStabilization/Buryanec-Commissioning-2023Commmissioning of I_p stabilization technology  |
---|
The session ID  | 45792  |
---|
The discharge comment | Commissioning into a chamber with max change of current, repeat #43673 |
---|
Discharge command  | /Dirigent.sh --discharge --operation.higherpower "voice='on',analysis='off',wg_voice='on',RawDataAcquiring='on',diagnostics_onstage='off',diagnostics_offstage='off',infrastructure= ... |
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=0,t_Bt=0,O_Bt='CW',U_cd=0,t_cd=1000,O_cd='CW'
Preionization
Parameters
:S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100
Working gas
Parameters
:S_mode='U_v',S_gas='H',p_H=15,U_v=19
Current stabilization: main_switch='on',waveform='1000,0;4000,-20;6000,20;8000,-20;10000,20;12000,0' |
 |
 |
 |
 |


|
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 