Tokamak GOLEM - Shot Database - #45803
![](http://golem.fjfi.cvut.cz/_static/qr.png)
| 24-08-13 13:23:08 [Shot logbook] |
---|
The session mission | Infrastructure/CurrentStabilization/Buryanec-Commissioning-2023Commmissioning of I_p stabilization technology ![](http://golem.fjfi.cvut.cz/_static/postgresql.webp) |
---|
The session ID ![](http://golem.fjfi.cvut.cz/_static/history.png) | 45792 ![](http://golem.fjfi.cvut.cz/_static/postgresql.webp) |
---|
The discharge comment | Commissioning into a chamber with max change of current, pridame E_CD |
---|
Discharge command![](http://golem.fjfi.cvut.cz/_static/help.png) ![](http://golem.fjfi.cvut.cz/_static/direct.png) | /Dirigent.sh --discharge --operation.higherpower "voice='on',analysis='off',wg_voice='on',RawDataAcquiring='on',diagnostics_onstage='off',diagnostics_offstage='off',infrastructure= ... |
On stage diagnostics
Basic diagnostics Data flow:
![](http://golem.fjfi.cvut.cz/_static/results.png)
Documentation:
Infrastructure
Chamber
Bt and Ecd
,![](http://golem.fjfi.cvut.cz/_static/direct.png)
Parameters
![](http://golem.fjfi.cvut.cz/_static/parameters.png)
:U_Bt=0,t_Bt=0,O_Bt='CW',U_cd=200,t_cd=1000,O_cd='CW'
Preionization
Parameters
:S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100
Working gas
Parameters
:S_mode='U_v',S_gas='H',p_H=15,U_v=19
Current stabilization