\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem #45835

Tokamak GOLEM - Shot Database - #45835

24-08-15 12:26:44 [Shot logbook]
The session missionExperiments/PlasmaRegimes/0624OptimizationFull steam
The session ID 45829
The discharge commentafter gd
Discharge command/Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='45744'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=375,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastruct ...

     Technological parameters

    No Plasma:

Basic Diagnostics    

On stage diagnostics

Basic diagnostics Data flow:  Documentation:

         

Off stage diagnostics

Interferometry Data flow:  Documentation:

         

Double rake probe Data flow:  Documentation:

Parameters:r_first_tip=100,X_mod='111111111111',I_SilverBox=0
         

Slow optical spectrometry Data flow:  Documentation:

         

Scintillation probes Data flow:  Documentation:

         

Langmuir & Ball-pen probe Data flow:  Documentation:

Parameters:r_lp_tip='90',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_d
         

Mirnov coils @ Limiter Data flow:  Documentation:

         

Fast spectrometry Data flow:  Documentation:

         

Strip detector Data flow:  Documentation:

         

Infrastructure

Chamber

Bt and Ecd ,

Parameters :U_Bt=1100,t_Bt=0,U_cd=375,t_cd=350,O_Bt='CW',O_cd='CW'

Preionization

Parameters :S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100

Working gas

Parameters :S_mode='p_pid',S_gas='H',p_H=10,U_v=0

Position stabilization :

Parameters :main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;20000,-20;40000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;19000,-20;40000,0'
 
 

Current stabilization

Parameters :main_switch='on',waveform='1000,0;15000,-20;20000,20;30000,-20;40000,0'

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Navigation