Tokamak GOLEM - Shot Database - #46205
| 24-09-02 10:35:59 [Shot logbook] |
---|
The session mission | Experiments/PlasmaRegimes/0624OptimizationFull steam |
---|
The session ID | 46203 |
---|
The discharge comment | test - standard good discharge |
---|
Discharge command | /Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=0,U_cd=325,t_cd=350,O_Bt='CW',O_cd='CW'" --infrastructure.preionization "S ... |
Plasma:
Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:
Documentation:
Off stage diagnostics
Interferometry Data flow:
Documentation:
Double rake probe Data flow:
Documentation:
Parameters:r_first_tip=100,X_mod='111111111111',I_SilverBox=0
Slow optical spectrometry Data flow:
Documentation:
Scintillation probes Data flow:
Documentation:
Langmuir & Ball-pen probe Data flow:
Documentation:
Parameters:r_lp_tip='90',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_d
Mirnov coils @ Limiter Data flow:
Documentation:
Fast spectrometry Data flow:
Documentation:
Strip detector Data flow:
Documentation:
Timepix detector Data flow:
Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd ,
Parameters
:U_Bt=1100,t_Bt=0,U_cd=325,t_cd=350,O_Bt='CW',O_cd='CW'
Preionization
Parameters :S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100
Working gas
Parameters :S_mode='U_v',S_gas='H',p_H=10,U_v=0
Position stabilization :
Parameters :main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;20000,-20;40000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;19000,-20;40000,0'
Current stabilization