Tokamak GOLEM - Shot Database - #47556
Time stamp | |
---|
| 25-01-15 13:47:45 |
[Shot logbook]The session mission | Experiments/PlasmaRegimes/0125OptimizationFull steam |
---|
The session ID | 47552 |
---|
The discharge comment | Currnet stab with no possition stab and modify vaweform |
---|
Discharge command | /Dirigent.sh --discharge --operation.discharge "style='standard',vacuum_shot='-1'" --infrastructure.bt_ecd "U_Bt=1100,t_Bt=5000,O_Bt='CW',U_cd=385,t_cd=5350,O_cd='CW'" --infrastruc ... |
On stage diagnostics
Basic diagnostics Data flow:
Documentation:
Off stage diagnostics
Interferometry Data flow:
Documentation:
Fast cameras Data flow:
Documentation:
Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=30,width_ux100a=1280,fr_ux100b=1
Slow optical spectrometry Data flow:
Documentation:
Scintillation probes Data flow:
Documentation:
Parameters:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600
Langmuir & Ball-pen probe Data flow:
Documentation:
Parameters:r_lp_tip='90',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_d
Timepix detector Data flow:
Documentation:
Mirnov coils @ Limiter Data flow:
Documentation:
Fast spectrometry Data flow:
Documentation:
Magnetohydrodynamic 16 mirnov coils ring Data flow:
Documentation:
Infrastructure
Chamber
Bt and Ecd ,
Parameters
:U_Bt=1100,t_Bt=5000,O_Bt='CW',U_cd=385,t_cd=5350,O_cd='CW'
Working gas
Parameters
:S_mode='p_wg',S_gas='H',p_H=15,U_v=0
Position stabilization :
Parameters
:main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'
Current stabilization