Tokamak GOLEM - Shot Database - #48019

[Shot logbook]
Time stamp | |
---|
| 25-03-10 17:59:29 |
---|
The session mission | Infrastructure/CurrentStabilization/Buryanec-CommissioningAETechron-2025Commmissioning of I_p stabilization technology |
---|
The session ID  | 47999  |
---|
The discharge comment | repeat 47990 reduce U_cd to 300V, reduce windings to 25,modify vaweform |
---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=1000,t_Bt=0,U_cd=300,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrast ... |
Plasma:

Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Fast cameras Data flow:

Documentation:

Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=30,width_ux100a=1280,fr_ux100b=1
Off stage diagnostics
Analysis
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=1000,t_Bt=0,U_cd=300,t_cd=1000,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=15,U_v=22
Position stabilization
:
Parameters

:main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;6000,-5;6000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'
Current stabilization
Parameters

:main_switch='on',waveform='1000,0;2000,2;10000,5;15000,10;25000,-10;30000,7;35000,-5;40000,0'
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 