Tokamak GOLEM - Shot Database - #48275

Time stamp | |
---|
| 25-03-25 16:18:06 |
[Shot logbook]The session mission | Experiments/RunAways/General/2025Full steam |
---|
The session ID  | 48275  |
---|
The discharge comment | testing 48251 as session standad |
---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=900,t_Bt=0,U_cd=350,t_cd=600,O_Bt='CW',O_cd='CW'" --infrastructure.workinggas "S_mod ... |
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Off stage diagnostics
Interferometry Data flow:
Documentation:
Slow optical spectrometry Data flow:
Documentation:
Scintillation probes Data flow:
Documentation:

Parameters:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600
Timepix detector Data flow:
Documentation:
Mirnov coils @ Limiter Data flow:
Documentation:
Fast spectrometry Data flow:
Documentation:
Magnetohydrodynamic 16 mirnov coils ring Data flow:
Documentation:
Double rake probe Data flow:
Documentation:

Parameters:r_first_tip=100,X_mod='111111111111',I_SilverBox=0
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=900,t_Bt=0,U_cd=350,t_cd=600,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=10,U_v=22
Position stabilization
:
Parameters

:main_switch='on',radial_switch='on',radial_waveform='1000,0;5000,-2;9000,-10;20000,-10;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-2;10000,-10;11000,-10;30000,0'
Biasing electrode 
Parameters

:main_switch='on',waveform='1000,0;3000,-20;15000,0;30000,0',position=100"
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 