Tokamak GOLEM - Shot Database - #48714

| Time stamp | |
|---|
| 25-04-24 16:57:33 |
[Shot logbook]| The session mission | Experiments/PlasmaRegimes/MinimumStabilizationFull steam |
|---|
The session ID  | 48712  |
|---|
| The discharge comment | Master test - positive I stab #48696 repeat with good techron canal orientation |
|---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=900,t_Bt=0,U_cd=375,t_cd=600,O_Bt='CW',O_cd='CW'" --infrastru ... |
Plasma:

Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Off stage diagnostics
Mirnov coils @ Limiter Data flow:
Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=900,t_Bt=0,U_cd=375,t_cd=600,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=15,U_v=22
Position stabilization
:
Parameters

:main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,-10;11000,0;16000,-10;21000,-18;30000,0',vertical_switch='on',vertical_waveform='1000,0;6000,-10;11000,-12;16000,-13;21000,-3;30000,0'
Current stabilization POKUS
Parameters
:main_switch='on',waveform='1000,0;4000,0;5000,0;8000,0;15000,0;17000,0;19000,0;20000,2;21000,4;22000,6;23000,8;24000,10;25000,12;26000,14;27000,16;28000,18;29000,20,35000,20'
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 