Tokamak GOLEM - Shot Database - #48799

| Time stamp | |
|---|
| 25-04-30 13:55:25 |
[Shot logbook]| The session mission | Experiments/PlasmaRegimes/MinimumStabilizationFull steam |
|---|
The session ID  | 48788  |
|---|
| The discharge comment | Repeat #48726 with positionstabilization and no currentstabilization, U_cd=300 volt, radial_stab is off repeat with glow discharge |
|---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.bt_e ... |
Plasma:

Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Fast cameras Data flow:

Documentation:

Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=40,width_ux100a=1280,fr_ux100b=1
Off stage diagnostics
Mirnov coils @ Limiter Data flow:
Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=900,t_Bt=0,U_cd=300,t_cd=600,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=10,U_v=22
Preionization
Parameters
:S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100
Position stabilization
:
Parameters
:main_switch='on',radial_switch='off',radial_waveform='1000,0;5000,-2;7000,-10;9000,-15;13000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,0;11000,-2;14000,-5;18000,-10;30000,0'
Current stabilization POKUS2
Parameters
:main_switch='off',waveform='1000,0;2000,0;5000,0;8000,0;15000,-8;16000,-6;17000,-4;18000,-2;19000,-1;20000,2;21000,4;22000,6;23000,8;24000,10;25000,12;26000,14;27000,15;28000,16;29000,15;30000,14;31000,12;32000,10;33000,8;34000,6;35000,4;36000,2;37000,-1;38000,-2;39000,-4;40000,-6;41000,-8;42000,-10;43000,-12;44000,-14;45000,-15;46000,-16;47000,-17;48000,0'
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 