Tokamak GOLEM - Shot Database - #48909

| Time stamp | |
|---|
| 25-05-15 16:20:53 |
[Shot logbook]| The session mission | Experiments/PlasmaRegimes/MinimumStabilizationFull steam |
|---|
The session ID  | 48908  |
|---|
| The discharge comment | Radial stab with AETechron - entree 2 |
|---|
Discharge command  | /Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=0,t_Bt=0,U_cd=0,t_cd=600,O_Bt='CW',O_cd='CW'" --infrastructure.workinggas "S_mode='p ... |
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Fast cameras Data flow:
Documentation:

Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=40,width_ux100a=1280,fr_ux100b=1
Off stage diagnostics
Mirnov coils @ Limiter Data flow:
Documentation:
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=0,t_Bt=0,U_cd=0,t_cd=600,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=10,U_v=22
Preionization
Parameters
:S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100
Position stabilization
:
Parameters
:main_switch='on',radial_switch='on',radial_waveform='1000,0;5000,-1;9000,-1;16000,-6;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-1;10000,-1;13000,-2;16000,-1;30000,0'
Current stabilization
Parameters
:main_switch='on',waveform='1000,0;4000,0;5000,0;8000,0;15000,-1;16000,-1;17000,-1;18000,-1;19000,1;48000,0'
 |
 |
 |
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 