Tokamak GOLEM - Shot Database - #48954

On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Fast cameras Data flow:
Documentation:

Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=40,width_ux100a=1280,fr_ux100b=1
Off stage diagnostics
Mirnov coils @ Limiter Data flow:
Documentation:
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=900,t_Bt=0,U_cd=0,t_cd=500,O_Bt='CW',O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',p_H=12,U_v=22
Preionization
Parameters
:S_device='HotCathode',SW_main='on',U_heater=90,U_accel=100
Position stabilization
:
Parameters
:main_switch='on',radial_switch='on',radial_waveform='1000,0;5000,-1;5500,-2;6000,-3;6500,-4;7000,-5;7500,-6;8000,-8;8500,-10;9000,-12;9500,-14;10000,-16;10500,-18;11000,-20;50000,0',vertical_switch='on',vertical_waveform='1000,0;5000,-1;6000,-2;7000,-3;8000,-4;9000,-5;10000,-6;11000,-8;12000,-10;13000,-12;14000,-14;15000,-16;17000,-18;19000,-20;50000,0'
Current stabilization