Time stamp
25-06-18 13:38:19
The session missionTrainingCourses/Universities/CTU.cz/TV@J/25/MiniprojektCommisioningBreakdown, plasma stabilization
The session ID 49260
The discharge commentMaster reverse curr stab
Discharge command/Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=400,t_cd=500,O_Bt='CW',O_cd='CW'" --infrastru ...

     Technological parameters

    Plasma:

    Plasma parameters:

Basic Diagnostics    

On stage diagnostics

Basic diagnostics Data flow:  Documentation:

         

Off stage diagnostics

Interferometry Data flow:  Documentation:

         

Fast cameras Data flow:  Documentation:

Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=40,width_ux100a=1280,fr_ux100b=1
         

Slow optical spectrometry Data flow:  Documentation:

         

Mirnov coils @ Limiter Data flow:  Documentation:

         

Fast spectrometry Data flow:  Documentation:

         

Magnetohydrodynamic 16 mirnov coils ring Data flow:  Documentation:

         

Analysis

NameAnalysis results


Infrastructure

Chamber

Bt and Ecd ,

Parameters :U_Bt=800,t_Bt=0,U_cd=400,t_cd=500,O_Bt='CW',O_cd='CW'

Working gas

Parameters :S_mode='p_wg',S_gas='H',p_H=10,U_v=22

Preionization

Parameters :S_device='HotCathode',SW_main='on',U_heater=90,U_accel=100

Position stabilization :

Parameters :main_switch='on',radial_switch='on',radial_waveform='1000,0;4000,0;5000,-2;7000,-4;9000,-4;10000,0;30000,0',vertical_switch='on',vertical_waveform='1000,0;5000,0;10000,-5;20000,-20;21000,0;32000,0;40000,0;50000,0'
 
 

Current stabilization

Parameters :main_switch='on',waveform='1000,0;6000,0;7000,4;7000,8;8500,10;9000,8;10000,0;40000,0'