Time stamp
25-11-04 12:28:23
The session missionInfrastructure/PositionStabilization/Dirigent-1125-AETechron4RadialStabCommmissioning the whole stabilization technology
The session ID 50342
The discharge commentAETechron 4 radial stab full commissioning 10V
Discharge command/Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=220,t_Bt=0,U_cd=220,t_cd=200,O_Bt='CW',O_cd='CW'" --infrastru ...

     Technological parameters

    No Plasma:

Basic Diagnostics    

On stage diagnostics

Basic diagnostics Data flow:  Documentation:

         

Infrastructure

Chamber

Bt and Ecd ,

Parameters :U_Bt=220,t_Bt=0,U_cd=220,t_cd=200,O_Bt='CW',O_cd='CW'

Working gas

Parameters :S_mode='p_wg',S_gas='H',p_H=15,U_v=22

Preionization

Parameters :S_device='HotCathode',SW_main='on',U_heater=90,U_accel=100

Position stabilization :

Parameters :main_switch='on',radial_switch='on',radial_waveform='1000,0;5000,0;10000,-10;15000,-10;20000,0;25000,10;30000,10;35000,0',vertical_switch='on',vertical_waveform='1000,0;5000,0;10000,-10;15000,-10;20000,0;25000,10;30000,10;35000,0'
 
 

Current stabilization

Parameters :main_switch='on',waveform='1000,0;2000,0;5000,-5;8000,0;9000,0;15000,0;17000,3;19000,7;21000,5;30000,0'