Tokamak GOLEM - Shot Database - #50466

Plasma:

Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:

Documentation:
Off stage diagnostics
Interferometry Data flow:

Documentation:
Slow optical spectrometry Data flow:
Documentation:
Fast spectrometry Data flow:
Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd
,
Parameters

:U_Bt=742.5,t_Bt=0,O_Bt='CW',U_cd=437.8,t_cd=229.5,O_cd='CW'
Working gas
Parameters

:S_mode='p_wg',S_gas='H',U_v=10,p_H=11.37
Preionization
Parameters
:S_device='HotCathode',SW_main='on',U_heater=90,U_accel=100
Position stabilization
:
Parameters
:main_switch='on',radial_switch='on',radial_waveform='1000,0;6000,0;6500,-0.0497479;6800,-0.0994959;8000,-0.348235;9000,-0.746219;12000,-0.994959;35000,0',vertical_switch='on',vertical_waveform='1000,0;5000,0;7000,-1.15126;9000,-2.68628;15000,0;17000,1.15126;19000,2.68628;21000,3.45379;23000,3.45379;25000,2.68628;30000,0'
Current stabilization
Parameters
:main_switch='on',waveform='1000,0;5000,0;7000,-4.94521;9000,-11.5388;15000,0;17000,4.94521;19000,11.5388;21000,14.8356;23000,14.8356;25000,11.5388;30000,0'
 |
 |
 |
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @ 