Date:
2012-09-20 -
18:59:12
Session:
SessionPreparation/2012
[new]
Comment:
USER_A - Discharge comment
Basic parameters:
(
compare
)
Gas pressure p
ch
:
1.45
->
20.04
mPa (request:
20
mPa)
WIKI
Working gas:
N/A
Preionization: ON
Chamber temperature:
N/A
C
C
B
t
capacitors changed to:
600 V
, triggered
5.0 ms
WIKI
C
BD
capacitors changed to:
0 V
, triggered
5.0 ms
WIKI
C
CD
capacitors changed to:
500 V
, triggered
6.0 ms
WIKI
C
ST
capacitors changed to:
0 V
, triggered
5.0 ms
WIKI
Probability of breakdown:
N/A
WIKI
Time since session beginning: 2:26:07 h
Plasma parameters:
Plasma life time
7.0
[ms] (from
7.8
to
14.8
)
Mean toroidal magnetic field Bt:
0.13
T
WIKI
Mean plasma current:
1.62
kA
WIKI
Mean Uloop:
9.22
V
WIKI
Break down voltage:
10.7
V
WIKI
Ohmic heating power:
14.91
kW
Q edge:
3.6
WIKI
Electron temperature:
17.9
eV
WIKI
Line electron density:
nan
[10^17.m^-2]
WIKI
WIKI
WIKI
WIKI
WIKI
basicdiagn processing evolution:
raw
→
integrated
→
final
Basic diagnostics:
loop_voltage
,
plasma_current
,
toroidal_field
,
photodiode
,
hxr
,
other diagnostics
Data Acquisition Systems (DAS):
TektronixDPO
NIstandard
Papouch
NIbasic
Papouch
Diagnostics:
PlasmaPosition
Flukes
Interferometer
FastCamera
Spectrometer
Analysis:
AdvancedAnalysis
HistoricalAnalysis
ShotHomepage
Impurities
Acknowledgement:
Thanks to the specific help
and
Diagnostics
✕
PlasmaPosition
✕
Flukes
✕
Interferometer
✕
FastCamera
✕
Spectrometer
Analysis
✕
AdvancedAnalysis
✕
HistoricalAnalysis
✕
ShotHomepage
✕
Impurities
DAS
✕
TektronixDPO
✕
NIstandard
✕
Papouch
✕
NIbasic
✕
Papouch
Vacuum log
Charging log
Other
Data
References
About
Wiki
Utilities
Navigation
Next
Previous
Current
Go to shot
[Main template]
Disk usage: 71MB
Navigation
current
next
|
previous
|