Revision dc710f89e3d7394f114aa2c2b184c2477cd356bf (click the page title to view the current version)

Education/ExperimentMenu/menu

  • Impact of engineering parameters such as the charging voltage of condenser banks for generation of the Toroidal magnetic \(U_{B_t}\) field and the Current in the primary winding of the GOLEM transformer \(U_{E_{CD}}\) on the plasma breakdown and on shot duration.

  • Measurement of the electron temperature together with focus on measurement procedure and uncertainty assessment.
  • Get the maximum plasma current \(I_p\) and see how it influences the shot duration, also proposing an explanation.
  • Get the maximum electron Temperature \(T_e\) varying Toroidal magnetic field \(B_t\) and Current drive \(U_{CD}\) and see how these influence the shot duration, also proposing an explanation.