Tokamak GOLEM - Shot Database - #44569
The date of discharge execution | 24-04-23 13:32:24 [Shot logbook] |
---|
The session mission | Infrastructure/SandboxFull steam |
---|
The session ID | 44564 |
---|
The discharge comment | MaTu test PID and ID in comment |
---|
Discharge command | /Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastr ... |
On stage diagnostics
Basic diagnostics Data flow:
Documentation:
Off stage diagnostics
Interferometry Data flow:
Documentation:
Magnetohydrodynamic 16 mirnov coils ring Data flow:
Documentation:
Double rake probe Data flow:
Documentation:
Parameters:r_first_tip=100,X_mod='111111111111',I_SilverBox=0
Slow optical spectrometry Data flow:
Documentation:
Scintillation probes Data flow:
Documentation:
Parameters:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600
Langmuir & Ball-pen probe Data flow:
Documentation:
Parameters:r_lp_tip='80',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_d
Timepix detector Data flow:
Documentation:
Mirnov coils @ Limiter Data flow:
Documentation:
Fast spectrometry Data flow:
Documentation:
Infrastructure
Chamber
Bt and Ecd ,
Parameters
:U_Bt=800,t_Bt=0,U_cd=450,t_cd=1000,O_Bt='CW',O_cd='CW'
Preionization
Parameters :S_device='HotCathode',SW_main='on',U_heater=100,U_accel=70
Working gas
Parameters :S_mode='p_pid',S_gas='H',p_H=6,U_v=22.0
Position stabilization :
Parameters :main_switch='off',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,-10;9000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'
Biasing electrode
Parameters :
Acknowledgement
Thanks to the specific help
The tokamak GOLEM controll SW @