Tokamak GOLEM - Shot Database - #46495
| 24-10-02 16:53:51 [Shot logbook] |
---|
The session mission | TrainingCourses/Universities/PUC.cl/24/entreeFull steam |
---|
The session ID | 46463 |
---|
The discharge comment | Demo for PUCcl 2024 Group 1 impurity_reference |
---|
Discharge command | /Dirigent.sh --discharge --operation.discharge "style='remote',voice='on',analysis='on'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,U_cd=600,t_cd=1000,O_Bt='CW',O_cd='CW'" --infrastr ... |
Plasma:
Plasma parameters:
On stage diagnostics
Basic diagnostics Data flow:
Documentation:
Slow optical spectrometry Data flow:
Documentation:
Fast spectrometry Data flow:
Documentation:
Off stage diagnostics
Interferometry Data flow:
Documentation:
Fast cameras Data flow:
Documentation:
Parameters:fr_ux100a=1200,height_ux100a=56,recrate_ux100a=40000,shotdur_ux100a=30,width_ux100a=1280,fr_ux100b=1
Motion detection
|
N/A |
|
|
South
|
North
|
Double rake probe Data flow:
Documentation:
Parameters:r_first_tip=100,X_mod='111111111111',I_SilverBox=0
Scintillation probes Data flow:
Documentation:
Parameters:U_NIM_A1=600,U_NIM_A2=600,U_NIM_A3=600,U_NIM_A4=600
Langmuir & Ball-pen probe Data flow:
Documentation:
Parameters:r_lp_tip=90,S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',U_lp=-1,R_lp_isat='-1',R_bpp_d
Mirnov coils @ Limiter Data flow:
Documentation:
Strip detector Data flow:
Documentation:
Parameters:acq_time=200,acq_delay=200,acq_mode='0'
Timepix detector Data flow:
Documentation:
Analysis
Infrastructure
Chamber
Bt and Ecd ,
Parameters :U_Bt=800,t_Bt=0,U_cd=600,t_cd=1000,O_Bt='CW',O_cd='CW'
Preionization
Parameters :S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100
Working gas
Parameters :S_mode='U_v',S_gas='H',p_H=10,U_v=18.2
Position stabilization :
Parameters :main_switch='on',radial_switch='on',radial_waveform='1000,0;10000,-20;20000,-20;40000,0',vertical_switch='on',vertical_waveform='1000,0;11000,-20;19000,-20;40000,0'
Current stabilization